Process Analyzers

Durkin supplies on-line analyzers for pH, conductivity, dissolved oxygen, combustion oxygen, humidity, liquid and gas density and process gas chromatography. Our analyzer solutions, probes, and associated controls ensure correct sampling, real-time feedback, and eliminate dead volume and contamination.

All analyzers are fully integrated and come in analyzer houses with HVAC, power distribution, piping and wiring, and gas/flame/explosion detection with appropriate class and division ratings. Learn more below or contact Durkin (314) 432-2040 for more information.

ABB ATS430 Sensor with Wiper

Overview

The ATS430 is a compact, yet extremely robust turbidity sensor capable of measuring turbidity and total suspended solids (TSS) concentrations up to 4000 NTU or 100,000 mg/l. With a choice of hermetically-sealed stainless steel or titanium versions, each featuring scratch-resistant sapphire optical windows, the ATS430 provides a versatile solution for use in benign environments through to those featuring aggressive or corrosive media. Supplied fully factory-calibrated ready for use straight out of the box. Users benefit from:
  • no servicing for the lifetime of the sensor
  • in-situ cleaning
  • advanced predictive maintenance diagnostics
  • EZLink automatic sensor recognition and set-up
  • adaptive TSS calibration feature for improved process control
  • simplified calibration
  • flexible installation
  • certified performance

Data

  • Range Turbidity: 0 to 4000 NTU Suspended solids: 0 to 100,000 mg/l SiO2 (100 g/l)
  • Accuracy Turbidity: <±2 % measured value Suspended solids: dependent on sample
  • Method 90° scattered light measurement in accordance with DIN/EN 27027/ISO 7027
  • Repeatability <1 %
  • Limit of detection 0.006 NTU
  • Response time T90 < 30 s with filtering disabled
  • Resolution Turbidity: 0.001 NTU Suspended solids: 0.001 mg/l
  • Storage conditions –5 to 70 °C (23 to 158 °F)
  • Operating temperature 0 to 60 °C (32 to 140 °F)
  • Operating pressure Up to 10 bar (145 psi) for metal versions
  • Dimensions 0 mm (1.57 in.) diameter 180 mm (7.08 in.) length
Category:
Process Analyzers
Sub-Category:
Tags:
ABB

Product Inquiry Form

Your Name (required)

Your Email (required)

Inquiry Product Name

Your Message

Analyzer Brands Carried by Durkin

What is the best sampling system for my analyzer?

Process sampling systems – the method by which you get reliable samples for your process analyzer – is just as important as analyzer selection. Unreliable or bad samples can cause major process line errors or false readings, leading to downtime and out-of-spec product.

There can  be several challenges to getting reliable samples, depending on your application. This video by Swaglok does a great job explaining some of the more common issues encountered:

As to which type of sampling system works best for your application, this is where Durkin’s half-a-century of experience working with process instrumentation can really help. Our specialists can help you select the right analyzer and setup a reliable sampling system complete with process controls, SCADA, and data collection.

To get oriented on the subject, you can check out Control Global’s “Introduction to Basic Sampling Systems“, or read about some of the more common types in this American Chemical Society article. An experienced analyzer technician is the recommended method for making sure you get the right sampling system and analyzer instrumentation.

Which analyzer is best for my application and where do I get pricing?

Every situation is unique and which analyzer you need, how much automation it should come with, and how much it will cost depends on many factors including your operating environment, flow rates, chemical composition and many other factors. Durkin’s process specialists can help you determine the specific analyzers and sampling systems that suit your application, budget, and expected life-span the best. Call (314) 432-2040 or contact us.

What are process analyzers?

Process analyzers are sensors and probes used to determine the chemical composition or physical properties of substances being manufactured. They provide real-time sampling and feedback to process controllers, so adjustments to the making process can be immediately effective in keeping products within specifications and the manufacturing process safe.

Most modern analyzers are auto-analyzers – a sample stream of flow from the process equipment is constantly going through the analyzer, which automatically makes process adjustments for pressure, temperature, flow rate, etc.

What are common types of process analyzers?

Process analyzers can be categorized several different ways.

The top level categories are:

Destructive analyzers vs non-destructive analyzers. Destructive analyzers modify the sample flowing to them so that it cannot be returned to the regular product stream. Non-destructive analyzers rely upon electromagnetic radiation, sound, and inherent material properties to measure samples so that they are not destroyed and can be returned to the regular product stream.

Online vs. Inline analysis – Online analyzers are connected to the process and conducts automatic sampling. Inline analyzers rely on sensors place in process vessels or stream to conduct the analysis.

Beyond these categories, more specific types of analyzers include:

  • Tunable diode lazer analyzers (TDLAS)
  • Oxygen analyzers
  • Paramagnetic oxygen analyzers
  • Infra-red gas analyzers
  • Dust monitoring systems
  • Mass flow meters
  • Gas chromotography detectors
  • Thermal conductivity detectors
  • Flame ionization detectors (FID)
  • pH analyzers
  • Conductivity analyzers
  • Temperature sensors

For a great run-down of how each of these work, their drawbacks and positives, check out this useful slideshare.